The Drager Fabius GS is an inhalation anesthesia machine used in an operating, induction, and recovery rooms. It can be used with O2, N2O, and AIR supplied by a medical gas pipeline system or have externally mounted gas cylinders. The Fabius GS is equipped with a compact breathing system that provides fresh gas decoupling, PEEP, and pressure limitation. This anesthesia machine has 5 main ventilation options that include; Volume Controlled Ventilation, Pressure Controlled Ventilation, Pressure Support, Manual Ventilation, and Spontaneous Breathing. It’s equipped with an electrically driven and electronically controlled ventilator that monitors for airway pressure (P), volume (V), and inspiratory oxygen concentration (FiO2).
The Drager Fabius GS anesthesia machine is a popular choice for practitioners who demand advanced ventilation technology combined with reliable and proven breathing system components. The Fabius GS anesthesia workstation opens new frontiers in ventilation performance while maintaining well-established functionality.
- High-performance ventilation with versatility that’s more flexible and economical to use than traditional gas-driven bellows ventilators
- Full-color screen
- Compact, convenient breathing system that’s ergonomically designed for optimal positioning
- ClinicalVision – monitoring solution that allows the caregiver to view patient monitoring and clinical data simultaneously
- Customized design for flexibility and ease of use
- Ready for IT-integration
- Low-flow ventilation
- Electronic vertical flow controls and electronic fresh gas flow indicators
- Intelligent cable management for reduced clutter and easier patient trans
- Easy integration into existing hospital information system
- Central braking
- Continuous monitoring during transport and automatic reconfiguration of site-specific parameters with Dräger’s innovative Infinity Docking Stations (IDS).
Features & Specifications
Drager Fabius GS Features
The Drager Fabius GS is an inhalation anesthesia machine used in an operating, induction, and recovery rooms. It can be used with O2, N2O, and AIR supplied by a medical gas pipeline system or have externally mounted gas cylinders. The Fabius GS is equipped with a compact breathing system that provides fresh gas decoupling, PEEP, and pressure limitation. This anesthesia machine has 5 main ventilation options that include; Volume Controlled Ventilation, Pressure Controlled Ventilation, Pressure Support, Manual Ventilation, and Spontaneous Breathing. It’s equipped with an electrically driven and electronically controlled ventilator that monitors for airway pressure (P), volume (V), and inspiratory oxygen concentration (FiO2).
The Drager Fabius GS anesthesia machine is a popular choice for practitioners who demand advanced ventilation technology combined with reliable and proven breathing system components. The Fabius GS anesthesia workstation opens new frontiers in ventilation performance while maintaining well-established functionality.
High-performance ventilation with versatility that’s more flexible and economical to use than traditional gas-driven bellows ventilators
Full-color screen
Compact, convenient breathing system that’s ergonomically designed for optimal positioning
ClinicalVision – monitoring solution that allows the caregiver to view patient monitoring and clinical data simultaneously
Customized design for flexibility and ease of use
Ready for IT-integration
Low-flow ventilation
Electronic vertical flow controls and electronic fresh gas flow indicators
Intelligent cable management for reduced clutter and easier patient trans
Easy integration into existing hospital information system
Central braking
Continuous monitoring during transport and automatic reconfiguration of site-specific parameters with Dräger’s innovative Infinity Docking Stations (IDS). Dimensions
Height (with COSY): 51.5″ (130.8 cm)
Width (with COSY): 35″ (89 cm)
Depth (with COSY): 33.1″ (84 cm)
Weight: 224 lbs (101.6 kg)
Power Supply
100 – 240 VAC, 50/60 Hz, 2.3 A max.
Battery (supports ventilator and monitor) > 45 min.
Rechargeable Batteries
Raitng: 24V; 3.5 Ah
Type: Sealed, gelled lead-acid
Recharge Time: ≤ 16 hours on the mains or full operation time
Operating time with fully charged batteries: 45 minutes, minimum
Ventilator Input Ranges
PMAX Pressure Limiting: 15 – 70 cmH2O (1 cmH2O resolution)
VT Tidal Volume: 20 – 1400 mL (10 mL resolution)
VT (SIMV/PS) Tidal Volume: 20 – 1100 mL (10 mL resoltuion)
f Breathing Frequency: 4 – 60 bpm (1 bpm resolution)
Ti/Te Inspiration/Expiration ration: 4:1 to 1:4
Tip/Ti Inspiration pause: 0% – 50% (1% resolution)
PEEP End-expiratory Pressure: 0 – 20 cmH2O (1 cmH2O resolution)
Pinsp Inspiratory Pressure: 5 – 65 cmH2O (1 cmH2O resolution)
Insp Flow Inspiratory Flow: 10 – 75 L/min (1 L/min resolution in Pressure Control Mode; 10 – 85 L/min (1 L/min resoltuion) in PS and SIMV/PS modes
Δ PPS (Pressure Support) Support Pressure: 3 – 20 cmH2O (1 cmH2O resolution)
Δ PPS (SIMV/PS) Support Pressur : 3 – 20 cmH2O, OFF (1 cmH2O resolution)
Freq Min Apnea Ventialtion minimum frequency: 2 – 20 bpm (1 bpm resolution) and “OFF”
Trigger: Trigger Level: 2 – 15 L/min (1 L/min resolution)
Tinsp SIMV Inspiratory Time: 0.3 – 4.0 sec
Pressure Support Ventilation Mode
Endotracheal Tube Size: 4.5 mm – 8 mm
Patient Lung Compliance: 10 ml/cmH2O – 100 ml/chH2O
Unassisted Patient Tidal Volume: 50 ml – 1000 ml
Patient Breath Rate (BPM): 10 – 35
Delivery Accuracy
Pmax Pressure Limiting: ±5 cmH2O of setting
VT Tidal Volume: ± 5% of setting or 20 mL, whichever is greater
f Breathing Frequency: ±1 bpm of setting
Ti/Te Inspiration/Expiration Ratio: ±5% of setting
Tip/Ti Inspiration Pause: ±25% of setting
PEEP End-expiratory Pressure: ±2 cmH2O or ±20% of setting, whichever is greater
Safety Reliefs
High Pressure Safety Relief Valve: 75 ±5 cmH2O
Negative Pressure Safety Relief Valve (Ambient Air Inlet Valve): -7.5 to -9 cmH2O
System Compliance Compenstation Measurement: 0.2 to .0 ml/cmH2O: ±0.2 ml/cmH2O or ±10% of actual complaince, whichever is greater
Anesthesia Gas Supply Module
Fresh Gas Flow Indicators: O2, N2O, Air: Range and accuracy: 0.0 to 12.0 L/min ±10% of reading or 0.12 L/min (into an ambient atmosphere of 14.7 psi (101.3 kPa) at 20°C). Resolution: 0.1 L/min
Fresh Gas Flow Stability: O2 and N2O: ±10% of setting with pipeline pressures between 45 – 65 psi; Air ±10% of setting with pipeline pressures between 50 – 55 psi; Air flow rate will vary proportionally with supply pressures outside 50 – 55 psi
Total Fresh Gas Flowmeter: Range and accuracy: 0 to 10 L/min ±10% of full scale at STP, calibrated with 50% O2 / 50% N2O gas mixture; 0 to 10 L/min ±15% of full scale at STOP for all other gas mixtures; Resoltuion: 0.5 L/min from 0.5 – 2 L/min; 1.0 L/min from 2 – 10 L/min
O2 Flush (bypass): at 55 psi (3.8 bar) max. 50 L/min; at 50 psi (3.4 bar) min. 35 L/min
Common Gas Outlet Pressure Limit: 13 psi (0.9 bar)
Anesthetic Agent Vaporizer Interface
The Drager Vapor quick-change plug-in system for up to two anesthetic agent vaporizers. The connections are automatically closed and sealed when the vaporizer is removed.
Drager Halothane Vapor
Drager Enflurane Vapor
Drager Isoflurane Vapor
Drager Sevoflurane Vapor
Datex-Ohmeda Devapor/D-Tech for Desflurane
Drager D-Vapor Warranty:
For new products, please refer to the manufacturer’s website for details.
This product has been refurbished and tested to the highest quality standards by The PCB Medical. This Limited Warranty offered by PCB Medical covers defects in material or workmanship. This warranty extends to the original purchaser only and is nontransferable. The warranty begins the day the equipment is received. Please inspect your item(s) upon delivery. Any unauthorized service providers working on our equipment within the warranty period will void the warranty!
Our warranty periods are very based on product, a standard 30 day parts warranty is included with all refurbished parts unless stated otherwise on the quote/Invoice. Warranties begin from the documented date of receipt.
Our warranties do not cover any problem that is caused by: A. Conditions, malfunctions or damage not resulting from defects in material or workmanship. B. Conditions, malfunctions or damage resulting from (1) normal wear and tear, improper installation, improper maintenance, misuse, abuse, negligence, accident or alteration.
Our limited warranties are void if a product is returned with removed, damaged or tampered labels or any alterations (including removal of any component or external cover).
PCB Medical will not provide any warranty coverage unless claims are made in compliance with all terms of the controlling warranty statement included with your product and you follow proper return procedure. To request warranty service, you will need to provide: 1. The invoice or other evidence of the date and place of purchase. 2. A description of the problem. 3. Contact our Customer Service Department to receive a Return Authorization Number (RMA#)
Shipping and Returns:
Damaged freight needs to be reported within 24 hours to file a claim. No merchandise may be returned without prior written authorization by PCB Medical.
No NEW merchandise may be returned unless authorization from manufacturer which could result in a restocking fee or no return at all, and customer is responsible for shipping expenses.
Return period for products is thirty (30) days from delivery or otherwise agreed upon.
The PCB Medical will test returned products returned and can impose a customer fee if the customer misrepresents the condition of the product.
CREDIT AND RETURN SHIPPING GUIDELINES
Order cancellations (after 24 hours) and returns are charged a 45% restocking fee. Damaged goods will receive credit dependent on the condition of the product, and customer is responsible for shipping expenses.
No credit will be issued if the item is non-returnable, such as a new product, custom or special order, or in the case that the item is damaged due to improper handling/packaging by the customer.
Shipping Charges: Customers are responsible for making sure items can be delivered into or outside of their facility without issue. For example, can a 53’ foot truck access your building? Failure to accommodate delivery can result in items not being delivered, additional fees, or return of equipment.
Basic Shipping Charge is for dock to dock shipping and/or liftgate service shipping. The items shipping dock to dock and/or liftgate are skidded/palletized items. It doesn’t not include inside delivery.
Residential shipping charge is for customer’s needing delivery in a residential area.
Inside delivery is for customer’s needing their purchase delivered inside the building. The item(s) will be delivered into the lobby only. They are not delivered into rooms/suites, elevators, or stairs.
Customers are responsible for disposing of packing materials.
If you are needing white glove delivery, please contact us directly at INFO@pcbhme.com