ADSII Anesthesia Delivery System

Workstation-class anesthesia delivery system. 8 ventilation modes, 15-inch touchscreen, pediatric-to-adult tidal volumes (10–1,500 mL), integrated heated absorber and 60-minute battery backup. CE · ISO 13485 · FDA Approved.

SKU: PCB-1775 Category: Brand:
Anesthesia Delivery System · ADSII · Workstation Class

ADSII Anesthesia Delivery System

Workstation-class anesthesia delivery system. 8 ventilation modes, 15-inch touchscreen, pediatric-to-adult tidal volumes (10–1,500 mL), integrated heated absorber and 60-minute battery backup.

8 ventilation modes15″ touchscreenPediatric → Adult60-min battery
ADSII Anesthesia Delivery System
8 modesVentilation
15″Touch TFT
10–1,500 mLTidal volume
60 minBattery backup
Overview

Workstation-class anesthesia delivery.

The ADSII Anesthesia Delivery System is a comprehensive workstation supporting eight ventilation modes (VCV, PCV, PRVC, SIMV(V)+PS, SIMV(P)+PS, CPAP/PSV, Manual, Standby) across the full patient range — pediatric/infant tidal volumes from 10 mL up to adult volumes of 1,500 mL in 5 mL increments. Large 15″ 1024×768 rotatable touchscreen displays 4 waveforms, 2 ventilation loops and 20+ parameters simultaneously. Integrated heated absorber with automatic water collection, compliance compensation, altitude compensation and 60-minute battery backup.

Key features

Built for anesthesia delivery.

🫁

8 ventilation modes

VCV · PCV · PRVC · SIMV(V)+PS · SIMV(P)+PS · CPAP/PSV · Manual · Standby — full range for every patient type and surgical scenario.

👶

Pediatric → adult

Tidal volumes 10 mL (infant/pediatric) up to 1,500 mL (adult) in 5 mL increments. Precision down to 15 mL for the smallest patients.

🖥

15″ rotatable touch

1024×768 TFT touchscreen displays 4 waveforms, 2 ventilation loops and 20+ parameters. Rotates for optimal viewing during procedures.

Used across clinical environments

Operating RoomSurgical CenterPediatric SurgeryAdult SurgeryHospital
Technical data

Specifications

Complete technical data.

Ventilation modesVCV · PCV · PRVC · SIMV(V)+PS · SIMV(P)+PS · CPAP/PSV · Manual · Standby (8)
Tidal volume pediatric10 – 300 mL
Tidal volume adult100 – 1,500 mL (5 mL increments)
O₂ flow0 – 10 L/min (electronic)
Air flow0 – 10 L/min (electronic)
N₂O flow0 – 10 L/min (electronic)
O₂ flush25 – 75 L/min
Display15″ TFT touchscreen, 1024×768, rotatable
Waveforms4 simultaneous + 2 ventilation loops
Parameters20+ (pressure, volume, compliance, resistance)
AbsorberIntegrated heated + automatic water collection
CompensationCompliance + altitude
Battery backup60 minutes
Optional modulesCO₂ · multi-gas · SpO₂ · vital signs integration
Certified quality
✓ FDA Approved